8 AC power connection CX-4 user manual
AC
POWER
CONNECTION
3
The CX-4 power supply must be wired to the voltage and frequency setting that
most closely matches the local AC supply. The factory setting is shown on the
serial number label.
Warning! For protection from fire and electric shock, the fixture must be
grounded (earthed). The power supply shall have overload and
ground-fault protection.
Warning! Verify that the feed cables are undamaged and rated for the
current requirements of all connected devices before use.
Important! Check the power supply setting before applying power.
Important! Do not connect the fixture to a dimmer system.
To install a plug on the mains lead
The mains lead must be fitted with a grounding-type cord cap that fits your
power distribution system. Consult a qualified electrician if you have any
doubts about proper installation.
Following the cord cap manufacturers instructions, connect the yellow and
green wire to ground (earth), the brown wire to live, and the blue wire to
neutral. The table below shows some pin identification schemes.
Wire Pin Marking Screw color
brown live “L” yellow or brass
blue neutral “N” silver
yellow/green ground green
Table 1: Cord cap wiring