10 AC power connection CX-4 user manual
3 The frequency setting (50 or 60 Hz) is selected by moving the black wire on
the ballast, which is located behind the effect wheel. To set for 50 Hz, move
the black wire to the “230-50” terminal. To set for 60 Hz, move the black wire
to the “230-60” terminal. See below. The wire is released and locked by
inserting a small screwdriver in the square hole next to the terminal and
prying back the spring.
4 Tug lightly on the black wire to make sure that it is connected securely.
5 Replace the top cover.