
6 Lamp CX-4 user manual
L
AMP
2
The CX-4 uses the Philips CDM-SA/T (short-arc, tubular) 150W discharge lamp.
If desired, the GE Arcstream 150 may be substituted.
The CX-4 can be modified with a different lamp socket that allows use of the
following lamps:
• Martin HTI 150 W, 2000 h
• OSRAM HTI 150 W, 750 h
• GE CSS 150 W, 1000 h
Please contact your Martin dealer for details.
Warning! Installing a lamp other than specified may be hazardous.
To install a lamp
Warning! Disconnect the fixture from AC power and allow the fixture to
cool before opening the fixture.
1 Remove 2 screws from the lamp-socket assembly with a Pozidriv #2
screwdriver. Remove the lamp assembly.
2 Remove the old lamp from the socket.
3 Holding the new lamp by its base (do not touch the glass), insert the lamp
pins squarely into the socket.
4 If your fingers touched the glass bulb, clean it with a clean, lint-free cloth
wetted with alcohol.
Lamp Efficiency Color Temp. Average Life
Philips CDM-SA/T 150W 85 Lm/W 4000 K 6000 h
GE Arcstream 150 77 Lm/W 4000 K 6000 h
Comentários a estes Manuais