Martin RoboColor III Manual do Utilizador Página 15

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 24
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 14
User Manual Service and Maintenance 15
VOLTAGE SETTINGS
It is essential that the voltage and frequency setting of your RoboColor III system
matches the mains supply. Otherwise damage may occur.
Warning! Disconnect the fixture from AC power before removing any cover.
To change the controller voltage setting
1 Access the transformer by removing the top cover.
2 On the transformer, move the BROWN wire to the correct voltage terminal. If
the mains voltage is between 210 and 240 volt use the 230 volt tap. If the
voltage is between 240 and 255 volt then use the 250 volt tap.
3 Re-assemble the unit.
To change the head voltage setting
1 Remove 6 screws from the back of the unit, as shown, and carefully withdraw
the entire rear assembly.
230V
250V
NEUTRAL.
Do NOT remove
BLUE wire.
Transformer
First, remove
these 6 screws.
Vista de página 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 23 24

Comentários a estes Manuais

Sem comentários