User Manual Service and Maintenance 13
LAMP REPLACEMENT
Warning! Disconnect the fixture from AC power before removing any cover.
To reduce the risk of the lamp shattering, never exceed the average lamp life,
listed below, by more than 25%. Disconnect the system from AC power if the
lamp blows. Allow the heads to cool for 15 minutes before installing a new lamp.
The RoboColor III comes with the Martin 150 W Metal Halide lamp installed.
The Osram HTI 150 and GE CSS 150 may be used as well.
Installing any other
lamp may damage the fixture.
To change the lamp
1 Remove the 3 thumbscrews that
secure the access plate of the lamp
socket assembly at the rear of the
head and withdraw the lamp socket
assembly.
2 Remove the old lamp from the
socket.
3 Holding the new lamp in a clean cloth
(do not touch the glass), carefully
insert it firmly and squarely into the
lamp socket.
4 If your fingers touch the glass, clean the bulb with a clean, lint-free cloth
wetted with alcohol.
5 Replace the lamp-socket assembly and tighten the thumbscrews.
Martin 150 W
Metal Halide Osram HTI 150 GE CSS 150
P/N 97010107 97010108 97010104
Average Life 2000 h 750 h 1000 h
Color Temp. 5000K 6500K 5000K
Output 900 lm 1200 lm 900 lm
Remove
screws.
Withdraw lamp socket assembly.
Hold only by the
ceramic base.
Do not touch the
glass