XLR-4 Cable Construction
Notes:
• It is very important to ensure that the drain wire from the cable shield is connected to both
XLR connector cases.
• Damage will occur if power connections short to the data, ground, or shield connections.
• When assembling XLR 4-pin cables, heat shrink should be used on each individual pin to
prevent short circuits. (See diagram below)
• Please take care when constructing these cables. A high percentage of problems are a direct
result of poor cable construction.
Detail of connector wiring (typical)
The correct wiring between male and female connectors is ‘one to one’.
XLR-4
Connector
(Pin No.)
Function Minimum Cable size
1 Ground (0 V) 2.50mm² (14 AWG)
2 Control data minus (-) 0.35mm² (22 AWG)
3 Control data plus (+) 0.35mm² (22 AWG)
Twisted data pair, with foil
shield and drain wire.
4 24 VDC (+ve) 2.50mm² (14 AWG)
Chassis Cable shield/Drain wire 0.25mm² (24 AWG)