Basic service 17
5 Replace the fixture cover and tighten the access screws, taking care not
to trap any loose wires.
GOBO REPLACEMENT OR REMOVAL
(EGO 2)
You can replace (or remove) the etched gobo in an Ego 2 with another
aluminium gobo that has:
• An outside diameter of 22.5 mm + 0/- 0.3 mm (0.886 in. +0/- 0.012 in)
• A maximum image diameter of 17 mm (0.669 in)
• A maximum thickness of 1.8 mm (0.071 in)
To replace (or remove) the gobo:
1 Unplug the mains cable from the input socket.
2 Remove the six access screws from the cover and lift it off. The gobo
holder is located between the lamp and the mirror dish.
3 Remove the thumb screw on the gobo holder and lift it out to access the
interchangeable gobo holder.
4 The currently installed gobo can be pressed out of the holder gently with
your thumb.
5 If you a replacing the gobo, create a gap using a flat head screwdriver,
and place the new gobo in the holder.
6 Return the gobo holder to its normal position.
7 Replace and tighten the thumb screw.
8 Replace the fixture cover and tighten the access screws, taking care not
to trap any loose wires.
FIRMWARE UPDATES
The factory installed firmware version is indicated on the serial number
label.
Firmware is installed using a Martin AVR Uploader and a PC. To install the
firmware update, prepare the AVR Uploader as described in its user
manual, connect the uploader to the AVR Upload socket on the control
panel, and apply power to the fixture. See the AVR user manual for more
information.