EFX600, EFX700 & EFX800, US models
AC power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110-120 VAC, 60 Hz nominal
Main fuse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.15 AT
Typical power and current*
@ 110 V, 60 Hz. . . . . . . . . . . . . . . . . . . . . . . . . . . 189 W, 1.8 A, PF = 0.963
@ 115 V, 60 Hz. . . . . . . . . . . . . . . . . . . . . . . . . . . 207 W, 1.9 A, PF = 0.964
@ 120 V, 60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . 226 W, 2.0 A, PF = 0.957
* V = volts, Hz = hertz, W = watts, A = amps, PF = power factor
Allow for a deviation of +/- 10% from typical figures listed above.
Measurements made at nominal voltage. Local supply voltages can vary by +/-10%.
Connections
Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-prong IEC male socket
Data in/out. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-pin locking XLR)
Thermal
Time required to cool before handling. . . . . . . . . . . . . . . . . . . . minimum 10 minutes
Maximum ambient temperature (T
a
) . . . . . . . . . . . . . . . . . . . . . .40° C (104° F)
EFX500, all models
Maximum surface temperature, steady state, T
a
= 40° C . . . . . . . . . . 100°C (212°F)
EFX600, EFX700 & EFX800, all models
Maximum surface temperature, steady state, T
a
= 40° C . . . . . . . . . . . 80°C (176°F)
Approvals
EU EMC . . . . . . . . . . . . . . . . . EN 55015, EN 61547, EN 61000-3-3, EN 61000-3-2
EU safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN 60598-1, EN 60598-2-17
US safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL 1573
Canadian safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..CSA C22.2 NO 166
Included items
EFX500, all models
Long-life 250 W halogen lamp
3 m (9.8 ft) EU mains cable 3x1.0mm
2
with Schuko male connector
3 m (9.8 ft) EU mains cable 3x1.0mm
2
with no male connector
2 m (6.5 ft) US mains cable 18AWG with US male connector (UL approved)
5 meter (16.4 ft.) RS-485 XLR cable for data link . . . . . . . . . . . . . . . . P/N 11820008
User manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 35000168
EFX600, EFX700 & EFX800, EU models
Long-life 150 W discharge lamp
3 m (9.8 ft) EU mains cable 3x1.0mm
2
with Schuko male connector
3 m (9.8 ft) EU mains cable 3x1.0mm
2
with no male connector
5 meter (16.4 ft.) RS-485 XLR cable for data link . . . . . . . . . . . . . . . . P/N 11820008