MAC 250 Krypton/Entour
user manual
Vista de página 0
1 2 3 4 5 6 ... 48 49

Resumo do Conteúdo

Página 1 - MAC 250 Krypton/Entour

MAC 250 Krypton/Entouruser manual

Página 2 - P/N 35000126 Rev. E

10 MAC 250 Krypton/Entour5 Install a safety cable that can bear at least 10 times the weight of the fixture securely to the structure andanchor the c

Página 3 - CONTENTS

Control Panel 11CONTROL PANELYou set the address and personalities, read out data, and execute service utilities from the control panel.Settings can

Página 4 - 4 MAC 250 Krypton/Entour

12 MAC 250 Krypton/Entour• PTSP, the pan/tilt speed menu, provides 3 settings: FAST, NORM and SLOW. NORM is best for most applications. FAST provides

Página 5 - NTRODUCTION

Control Panel 13FIRMWARE VERSIONINFO>VER displays the firmware version number. The firmware version is also displayed briefly atstartup. Test and

Página 6 - 6 MAC 250 Krypton/Entour

14 MAC 250 Krypton/EntourDMX-512 CONTROLThe MAC 250 Krypton/Entour is compatible with USITT DMX512 controllers. The full protocol is available in “DM

Página 7 - AC power

DMX-512 control 15angle or rotation speed are selected on channel 5 (channel 7 in 16-bit Extended mode). Fine tuning of thisindex position or rotatio

Página 8 - Frequency

16 MAC 250 Krypton/Entourprovides smoother movement, particularly at slow speeds, with controllers that send slow or irregulartracking updates. When

Página 9 - Installation

Optical configuration 17OPTICAL CONFIGURATIONGOBO ORIENTATIONFigure 3 shows the correct orientation for different gobo types. When in doubt, install

Página 10 - 10 MAC 250 Krypton/Entour

18 MAC 250 Krypton/EntourSTANDARD ROTATING GOBO CONFIGURATIONThe MAC 250 Krypton/Entour provides 7 gobos as shown below.REPLACING A GOBODanger! Inten

Página 11 - Tailoring performance

Optical configuration 194 Remove the gobo holder from the gobo wheel.5 Squeeze the ends of the retention spring together and remove. Push the gobo ou

Página 12 - Information readouts

All measurements are expressed in millimeters393375538469364119315270°270°560270°128.5°128.5°© 2004 Martin Professional A/S, Denmark. All rights reser

Página 13 - Test and service utilities

20 MAC 250 Krypton/EntourFixed gobos (MAC 250 Entour only)The MAC 250 Entour provides 10 fixed gobo positions (plus open).REPLACING A FIXED GOBODange

Página 14 - DMX-512

Optical configuration 214 Push and slide the gobo out of position5 Insert the replacement gobo into the holder. Secure the gobo with the retention fe

Página 15 - Speed control

22 MAC 250 Krypton/Entour REPLACING A COLOR FILTERDanger! Intense heat. Avoid contact by persons and materials. The exterior of the fixture can get v

Página 16 - PERSONALITY OVERRIDES

Optical configuration 232 Remove the top cover. The top and bottom cover look the same, but the top cover is found by checking ifthe text on the back

Página 17 - CONFIGURATION

24 MAC 250 Krypton/Entour5 Using a Philips screwdriver, remove the half-circle shaped plate that holds the prism into place (as indicatedin this illu

Página 18 - Figure 3: MAC 250

Optical configuration 253 Using a flathead screwdriver, remove the two retaining plates (only one - at position A - is illustrated here)holding the p

Página 19 - Optical configuration 19

26 MAC 250 Krypton/Entour7 Replace the rubber drive belt over the rotating prism and screw the half-circle shaped plate into place. Theprism should b

Página 20 - REPLACING A FIXED GOBO

Optical configuration 274 Remove the three Phillips screws and lift the plate off the effect module.5 Remove the four Phillips screws.6 Lift the lens

Página 21 - Color filters

28 MAC 250 Krypton/EntourSERVICEThe MAC 250 Krypton/Entour requires regular maintenance to keep performing at their peak. Excessivedust, grease, and

Página 22 - REPLACING A COLOR FILTER

Service 29power and allow it to cool for at least 45 minutes before proceeding. Wear safety goggles to protect your eyes. 1 Locate the lamp access co

Página 23 - Optical configuration 23

CONTENTSINTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5Features

Página 24 - 24 MAC 250 Krypton/Entour

30 MAC 250 Krypton/EntourFANTo maintain adequate cooling it is important that the fan be cleaned regularly. It can be cleaned with a softbrush, vacuu

Página 25 - Optical configuration 25

Service 31Updating softwareThe latest MAC 250 Krypton/Entour firmware is available from the support area of the Martin web site atwww.martin.dk. It c

Página 26 - 26 MAC 250 Krypton/Entour

32 MAC 250 Krypton/EntourDMX PROTOCOLThis chapter contains:• “MAC 250 Krypton DMX protocol” on page 33• “MAC 250 Entour DMX protocol” on page 36

Página 27 - Optical configuration 27

DMX protocol 33MAC 250 Krypton DMX protocol16 Bt(16 Bit Mode)16 Ex(16 Bit Extended) Value Percent Function11If DMX Reset is disabled in the menu, a r

Página 28 - Lamp replacement

34 MAC 250 Krypton/Entour460 - 45 - 1011 - 1516 - 2021 - 2526 - 3031 - 3536 - 4243 - 5051 - 5859 - 6566 - 7374 - 8182 - 8990 - 9697 - 104105 - 119120

Página 29 - Cleaning

DMX protocol 3513 160 - 2 3 - 245246 - 248249 - 251252 - 2550 - 11 - 9696 - 9798 - 9899 - 100Pan/Tilt SpeedTrackingFast → slowTracking, PTSP NORM (me

Página 30 - Replacing fuses

36 MAC 250 Krypton/EntourMAC 250 Entour DMX protocol16 Bt(16 Bit Mode)16 Ex(16 Bit Extended) Value Percent Function11If DMX Reset is disabled in the

Página 31 - Updating software

DMX protocol 37460 - 45 - 1011 - 1516 - 2021 - 2526 - 3031 - 3536 - 4243 - 5051 - 5859 - 6566 - 7374 - 8182 - 8990 - 9697 - 104105 - 119120 - 134135

Página 32 - PROTOCOL

38 MAC 250 Krypton/Entour8100 - 255 0 - 100FocusInfinity → 2 meters11 0 - 255 0 - 100 Focus (Lowest Significant Byte) 9120 - 1920 - 7980 - 89 90 - 1

Página 33 - MAC 250 Krypton DMX protocol

Control menu 39CONTROL MENU Options displayed in bold represent the default settings.Menu Item Options Notes (Default settings in bold print)AddR - 1

Página 35 - DMX protocol 35

40 MAC 250 Krypton/EntourINFOTIME/L HRRSETHours of operation since counter reset. To reset, display counter and press [up] for 5 seconds.TOTL Total h

Página 36 - MAC 250 Entour DMX protocol

Control menu 41MAN RST - Reset fixtureL ON - Lamp onLoFF - Lamp offSHUT OPEN Open shutterCLOS Close shutterSTRF Fast strobeSTRM Medium strobeSTRS Slo

Página 37 - DMX protocol 37

42 MAC 250 Krypton/EntourMAN(cont.)PRIS ON Prism inOFF Prism outCWF Clockwise rotation - fastCCWF Counter-clockwise rotation - fastCWM Clockwise rota

Página 38 - 38 MAC 250 Krypton/Entour

Error messages 43ERROR MESSAGESDisplay readout Appears if... What to doMERR (Memory error) ...the EEPROM memory cannot be read. • Contact service tec

Página 39 - Control menu 39

44 MAC 250 Krypton/EntourTROUBLESHOOTINGProblem Probable cause(s) RemedyOne or more of the fixtures is completely dead.No power to fixture. • Check t

Página 40 - 40 MAC 250 Krypton/Entour

Circuit board connections 45CIRCUIT BOARD CONNECTIONS33120043-BTemp HeadTemp HeadLight SensorLight Sensor14 1513TiltF.B.TiltF.B.PanF.B.PanF.B.Temp On

Página 41 - MAN RST - Reset fixture

46 MAC 250 Krypton/EntourSPECIFICATIONS - MAC 250 KRYPTONPHYSICALBase length. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 42 - 42 MAC 250 Krypton/Entour

Specifications - MAC 250 Krypton 47CONTROL AND PROGRAMMINGData input. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 43 - MESSAGES

48 MAC 250 Krypton/EntourSPECIFICATIONS - MAC 250 ENTOURPHYSICALBase length. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 44 - ROUBLESHOOTING

Specifications - MAC 250 Entour 49CONTROL AND PROGRAMMINGData input. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 45 - CONNECTIONS

Introduction 5INTRODUCTIONThank you for selecting the Martin MAC 250 Krypton or the MAC 250 Entour. FeaturesSome of the many features include: • effi

Página 46 - - MAC 250 K

6 MAC 250 Krypton/Entour• Use only a source of AC power that complies with local building and electrical codes and has both overload and ground-fault

Página 47

Setup 7SETUPUnpackingThe MAC 250 Krypton/Entour comes with:• MSD 250/2 lamp (factory installed)• 3-meter, 3-wire IEC power cable• user manual• 1/4-tu

Página 48 - - MAC 250 E

8 MAC 250 Krypton/EntourCONFIGURING FOR LOCAL AC POWER1 Disconnect the fixture from power. 2 Remove the 2 Phillips screws in the access cover directl

Página 49 - Entour narrow

Setup 9InstallationLOCATION AND ORIENTATIONThe MAC 250 Krypton/Entour may be installed in any orientation. It can be fastened directly to a suitables