Martin MAC 101 Series Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Controladores de DJ Martin MAC 101 Series. Martin MAC 101 Series User manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - MAC 250 Krypton

MAC 250 Kryptonuser manual

Página 2 - P/N 35000126 Rev. A

10 MAC 250 Krypton3 To terminate the link, insert a male 120 Ω XLR termination plug in the output of the last fixture. TIPS FOR BUILDING A SERIAL LIN

Página 3

Control Panel 11CONTROL PANELYou set the address and personalities, read out data, and execute service utilities from the control panel.Settings can

Página 4 - NTRODUCTION

12 MAC 250 Kryptonwhere you want some fixtures to mirror the performance of others with the same DMX address, or when fixtures are not oriented as pr

Página 5 - Introduction 5

Control Panel 13LAMP STRIKESRead the total number of lamp strikes (INFO>TIME>L ST>TOTL), and the number of lamps strikessince the counter wa

Página 6 - Lamp installation

14 MAC 250 KryptonUPLOAD MODEThe upload mode command (UTIL>UPLd) prepares the fixture for a software update. This command isnot necessary, however

Página 7 - AC power

DMX-512 control 15DMX-512 CONTROLThe MAC 250 Krypton is compatible with USITT DMX512 controllers. The full protocol is available in “DMXprotocol” on

Página 8 - Installation

16 MAC 250 Kryptonrotation speed are selected on channel 5 (channel 7 in 16-bit Extended mode). Fine tuning of this indexposition or rotation is avai

Página 9 - Setup 9

Optical configuration 17OPTICAL CONFIGURATIONGobos The MAC 250 Krypton accepts up to eight metal or glass gobos with an outside diameter of 22.5 mm a

Página 10 - 10 MAC 250 Krypton

18 MAC 250 Krypton2 Remove the top cover of the fixture head using a flathead screwdriver to loosen the four quarter-turnscrews. The top and bottom c

Página 11 - Tailoring performance

Optical configuration 197 Insert the gobo holder back in the gobo wheel using a small flathead screwdriver to lift the retaining blades.8 Replace the

Página 12 - Information readouts

All measurements are expressed in millimeters393375538469364119315270°270°560270°128.5°128.5°© 2001-2002 Martin Professional A/S, Denmark. All rights

Página 13 - Test and service utilities

20 MAC 250 KryptonColor filtersSTANDARD CONFIGURATIONThe MAC 250 Krypton provides 12 dichroic color filters as shown below. REPLACING A COLOR FILTERD

Página 14 - UPLOAD MODE

Optical configuration 214 Turn the color wheel to access the desired color filter. Press thefilter forwards slightly to release it and then grasp it

Página 15 - DMX-512

22 MAC 250 Krypton3 Using a flathead screwdriver, remove the two retaining plates (only one - at position A - is illustrated here)holding the prism m

Página 16 - Speed control

Optical configuration 237 Replace the rubber drive belt over the rotating prism and screw the half-circle shaped plate into place. Theprism should be

Página 17 - CONFIGURATION

24 MAC 250 KryptonSERVICEThe MAC 250 Krypton requires regular maintenance to keep performing at their peak. Excessive dust,grease, and smoke fluid bu

Página 18 - 18 MAC 250 Krypton

Service 25LubricationUse only silicone lubricant, Martin P/N 37302003 (500 ml) or P/N 37302004 (200 ml, in applicator bottle).No other lubricant is a

Página 19 - GOBO ORIENTATION

26 MAC 250 KryptonUpdating softwareThe latest MAC 250 Krypton firmware is available from the support area of the Martin web site atwww.martin.dk. It

Página 20 - Color filters

DMX protocol 27DMX PROTOCOLA16 Bt(16 Bit Mode)16 Ex(16 Bit Extended) Value Percent Function11If DMX Reset is disabled in the menu, a reset command ca

Página 21 - REPLACING THE PRISM

28 MAC 250 Krypton5 0 - 255 0 - 100 Color (Lowest Significant Byte) 460 - 45 - 1011 - 1516 - 2021 - 2526 - 3031 - 3536 - 4243 - 5051 - 5859 - 6566 -

Página 22 - 22 MAC 250 Krypton

DMX protocol 2912 150 - 255 0 – 100Tilt Fine (Lowest Significant Byte) Left → right13 160 - 2 3 - 245246 - 248249 - 251252 - 2550 - 11 - 9696 - 9798

Página 23 - Optical configuration 23

INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4Features . . . .

Página 24 - Cleaning

30 MAC 250 KryptonCONTROL MENUBOptions displayed in bold represent the default settings.Menu Item Options Notes (Default settings in bold print)AddR

Página 25 - Exterior surfaceto

Control menu 31INFOTIME/L HRRSETHours of operation since counter reset. To reset, display counter and press [up] for 5 seconds.TOTL Total hours of op

Página 26 - InitLock

32 MAC 250 KryptonMAN RST - Reset fixtureL ON - Lamp onLoFF - Lamp offSHUT OPEN Open shutterCLOS Close shutterSTRF Fast strobeSTRM Medium strobeSTRS

Página 27 - PROTOCOL

Control menu 33MAN(cont.)PRIS ON Prism inOFF Prism outCWF Clockwise rotation - fastCCWF Counter-clockwise rotation - fastCWM Clockwise rotation - med

Página 28 - 28 MAC 250 Krypton

34 MAC 250 KryptonERROR MESSAGESCDisplay readout Appears if... What to doMERR (Memory error) ...the EEPROM memory cannot be read. • Contact service t

Página 29 - DMX protocol 29

Troubleshooting 35TROUBLESHOOTINGDProblem Probable cause(s) RemedyOne or more of the fixtures is completely dead.No power to fixture.• Check that pow

Página 30 - 30 MAC 250 Krypton

36 MAC 250 KryptonCIRCUIT BOARD CONNECTIONSE

Página 31 - Control menu 31

Specifications - MAC 250 Krypton 37SPECIFICATIONS - MAC 250 KRYPTONPHYSICALBase length. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 32 - MAN RST - Reset fixture

38 MAC 250 KryptonDESIGN STANDARDSCanadian safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 33 - Control menu 33

Specifications - MAC 250 Krypton 39Intensity as function of distance11010010001000010000010000001 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16Distance [m]In

Página 34 - MESSAGES

4 MAC 250 KryptonINTRODUCTIONThank you for selecting the Martin MAC 250 Krypton. FeaturesSome of the many features include: • efficient, 2000 hour, 2

Página 35 - ROUBLESHOOTING

Introduction 5• Use only a source of AC power that complies with local building and electrical codes and has both overload and ground-fault protectio

Página 36 - CONNECTIONS

6 MAC 250 KryptonSETUPUnpackingThe MAC 250 Krypton comes with:• MSD 250/2 lamp (not installed)• 3-meter, 3-wire IEC power cable• user manual• 1/4-tur

Página 37 - - MAC 250 K

Setup 72 Pull out the lamp socket. 3 If changing the lamp, remove the old lamp from the socket.4 Holding the new lamp by its ceramic base (do not tou

Página 38 - PHOTOMETRICS

8 MAC 250 Krypton4 Move the voltage switch to the setting that most closely matches the local AC voltage. If your voltage fallshalfway between 2 sett

Página 39

Setup 9The MAC 250 Krypton includes an omega clamp mounting bracket to which 1 or 2 rigging clamps (notincluded) can be bolted. The clamp mounting br

Comentários a estes Manuais

Sem comentários